CES-FD-AP-M-01-USI-115534 Euchner Vietnam
CES-FD-AP-M-01-USI-115534 (Order no. 115534) hiện đang được HandHeld phân phối tại thị trường Việt Nam, ứng dụng trong hầu hết lĩnh vực…
CES-FD-AP-M-01-USI-115534 (Order no. 115534)
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection values
Fuse | |
external (operating voltage) | 0.25 … 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB (PELV, see operating instructions) (reverse polarity protected, regulated, residual ripple<5%) | 24 V DC -15% … +15% |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Safety class | III |
Current consumption | max. 45 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety outputs FO1A / FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 … 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1.5V … UB V DC |
rated conditional short-circuit current | 100 A |
Discrepancy time | max. 10 ms |
Utilization category | |
DC-13 | 24 V 150 mA |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output | 1 … 150 mA |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 100 ms |
Mechanical values and environment
Connection type | Connecting cable PUR with plug connector M12, 5-pin; pin 5 not used |
Tightening torque | max. 1 Nm |
Ready delay | 1 s |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP67 |
Cable ambient temperature (dynamic) | -5 … +65 °C |
Cable ambient temperature (static) | -20 … +65 °C |
Material | |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.5 x 10-9 |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB
Switch-on distance | 5 mm |
Secured switch-off distance sar | max. 10 mm |
Secured switching distance sao | min. 3.4 mm |
Switching hysteresis | 0.05 … 0.2 mm |
Field evaluation unit CES-FD-AP-…
- Connection of a CES/CKS read head
- Evaluation of signals in the field
- Connection to the ET200s and ET200pro
- Familiar EUCHNER AP interface
- Multicode
Euchner Vietnam
SR11WF (ORDER NO. 054773) |
NZ2HS-3131 (ORDER NO. 090856) |
TX3B-A024MC1991 (ORDER NO. 085391) |
106159 |
106159 |
CES-A-LNA-SC-077715 |
124225 |
111080 |
ORDER NO. 113187 |
113187 |
73457 |
73456 |
73455 |
113187 |
104302 + 100464 |
082051 + 076200 |
CES-AZ-AES-01B |
121026 |
110906+123433+100179+100185+100181 |
Đánh giá